This database is not maintained anymore and will be shut down shortly. Please use the Z-Wave Alliance Product Catalogue as an alternative.
Login

Device Description

Product Name: Doorbell Gen5
Brand Name: Aeotec
Product Line: Z-wave Product Line
Product Code: ZW056-A
Product Version:
Product Comment:
Battery Type:
Battery Count:
Description: Doorbell Gen5
Inclusion Note: Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing.
Wakeup Note:
 
Default Image: Not available

Device Data

Hash Weak: 04-10-05
Hash Strong: 0086-0104-0038-03-04-05-01-00
Manufacturer: AEON Labs (0x0086)
Product Type ID: 0x0104
Product ID: 0x0038
Library Type: 0x03
Protocol Version: 0x04
Protocol Sub Version: 0x05
Application Version: 0x01
Application Sub Version: 0x00
Basic Class: Slave with routing capabilities
Generic Class: Binary Switch
Specific Class: Siren
Optional Flag: Yes
Listening Flag: Yes
Routing Flag: Yes
Beam Sensor
RF Frequency US
Certification ID:
Certification Number:
Submitter: tolo
Create time: 2015-10-27 13:31:25
Last changed: 2015-10-27 14:23:12

Implemented Command Classes

Command Class Byte Version Support Control In NIF Secure Non Secure
Association 0x85 2 Yes No Yes No Yes
Association Command Configuration 0x9B 1 Yes No Yes No Yes
Basic 0x20 1 Yes No Yes No Yes
Binary Switch 0x25 1 Yes No Yes No Yes
Configuration 0x70 1 Yes No Yes No Yes
Device Reset Locally 0x5A 1 Yes No Yes Yes Yes
Energy Production 0x90 2 Yes No Yes No Yes
Hail 0x82 1 No Yes Yes Yes Yes
Manufacturer Specific 0x72 2 Yes No Yes No Yes
Powerlevel 0x73 1 Yes No Yes No Yes
Security 0x98 1 Yes No Yes Yes Yes
Version 0x86 2 Yes No Yes Yes Yes
Z-Wave+ Info 0x5E 2 Yes No Yes Yes Yes

Config Parameters

Paramter No. 2 Size 1 Default 2
Name Doorbell Repetitions
Description Set the repetitions for playing doorbell ringtone. Note: If the time of playing doorbell ringtone is more than 20s, the volume of ringtone will reduce to silence no matter how many repetitions of doorbell ringtone are set.
Type rangemapped
Values
0   ->   ignore
1 - 100   ->   Define number of repetitions.
 
Paramter No. 5 Size 1 Default 1
Name Doorbell Ringtone
Description Set the default doorbell ringtone.
Type range
Values
1 - 100   ->   Define a ringtone.
 
Paramter No. 6 Size 1 Default 0
Name Select a Ringtone to Play
Description
Type rangemapped
Values
0   ->   Stop playing.
1 - 100   ->   Play the specified ringtone.
 
Paramter No. 7 Size 1 Default 0
Name Control Items
Description
Type constant
Values
1   ->   play
2   ->   stop
3   ->   pause
4   ->   next
5   ->   previous
 
Paramter No. 8 Size 1 Default 10
Name Volume
Description Set the volume of ringtone.
Type range
Values
0 - 10   ->   Define the volume.
 
Paramter No. 10 Size 1 Default 0
Name Button Functions
Description Define functions of “Button -” and “Button+”.
Type constant
Values
0   ->   “Button -” is previous, “Button+” is next
1   ->   Swap functions of the two buttons.
 
Paramter No. 11 Size 1 Default 0
Name Button Functions/ Input Options
Description Define the function of Button- and Button+ when pressing it once and long pressing it.
Type constant
Values
0   ->   Pressing it once, which will change the volume. Long pressing it, which will change the default ringtone.
1   ->   Pressing it once, which will change the default ringtone. Long pressing it, which will change the the volume.
 
Paramter No. 42 Size 1 Default 0
Name Battery Status
Description Get Wireless Button battery status.
Type constant
Values
0   ->   Read only: Normal battery level
1   ->   Read only: Low battery level
0   ->   Set value: Low battery alarm is cancelled
 
Paramter No. 80 Size 1 Default 0
Name Type of Notifications
Description Enable/disable to send notifications to associated devices when the state of Doorbell is changed.
Type constant
Values
0   ->   Send Nothing (Disabled)
1   ->   Send HAIL Command
2   ->   Send BASIC Report Command
 
Paramter No. 81 Size 1 Default 1
Name Notifications Low Battery State
Description Enable/disable to send notifications to associated devices (Group 1) when the Wireless Button’s battery is in low battery state.
Type constant
Values
0   ->   disable
1   ->   enable
 
Paramter No. 241 Size 4 Default
Name Pair the Wireless Button with Doorbell
Description Start the Wireless Button pairing mode and the blue Led will blink slowly, short press the Wireless Button once, if the blue Led change to be solid, which means the pairing is successful. Otherwise, repeat the steps. It will automatically exit the pairing mode after 8s if there is no pressing action of the Wireless Button. Note: You can send this configuration Get CC to ask the pairing result: If configuration report value=0x00000000, which means the pairing is failed. If configuration report value =0xFFFFFFFF, which means the pairing is successful.
Type constant
Values
1431655765   ->   Start the Wireless Button pairing mode.
 
Paramter No. 252 Size 1 Default 0
Name Lock Configuration
Description Enable/Disable Lock Configuration.
Type constant
Values
0   ->   All configuration parameters are configurable.
1   ->   All configuration parameters are not configurable (Locked).
 
Paramter No. 255 Size 4 Default
Name Reset to default factory setting
Description
Type constant
Values
1   ->   Resets all configuration parameters to default setting.
1431655765   ->   Reset the product to default factory setting and be excluded from the Z-wave network.
 

Association Groups

Group Number Max Nodes Description
1 5 Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate. When the Doorbell is received the commands sent by controller to be turned on or off, the Doorbell will send a basic report of its status to the nodes in association group 1. To change what kind of signal is sent to the nodes in group 1, please see the detailed description of configuration parameter 80.
2 5 When the Doorbell receives the Basic Set, Switch Binary Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set commands from main controller. it will forward the Basic Set, Switch Binary Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set to associated nodes in Group 2.

Endpoints

Alarm Mappings

 

Back to list, XML